:: Volume 5, Issue 4 (Quarterly 2002) ::
Feyz Med Sci J 2002, 5(4): 54-60 Back to browse issues page
Evaluation of elimination of fecal Coliforms in sewage fixation ponds
Mohamamd Bagher Miranzaeh * , Amir Hossein Mahvi
, miranzadeh_mb@kaums.ac.ir
Abstract:   (10605 Views)

History and Objectives: Exited sewage following mechanical methods contains pathogenic agents. Therefore, swage clearance with chlorine and other compounds is necessary. It has been reported that in fixation ponds with regard to a long-time standing, there is a high rate of clearance and there is no need of additional clearance and this reduces the costs. Therefore, this study was carried out to determine the clearance rate of fecal coliforms in fixation ponds of Shoosh sewage refinery in Tehran in 1999.

Materials and Methods: The semi-experimental strategy of this study was carried out on integrated stabilization pond in all of the seasons using two feeding sewage methods. The system is a combination of anaerobic and facultative ponds and then two high-performance and complementary with a total time of 20 days. Sampling was done every two weeks from inlet and outlet sewage and number of fecal coliforms was counted and data were analyzed statistically.

Results: It was found out that clearance rate of fecal coliforms was greater in spring than other seasons (99.97%) and was rather great in winter (Greater than 99.5%). This indicates the high performance of the system for clearance of pathogenic agents from sewage.

Conclusion and Recommendations: It is concluded that combinational fixation ponds have an appropriate performance for clearance of pathogenic agents. Feeding through upward current can increase the performance, as does the facultative pond. It is recommended to carry out more studies in this field.

Keywords: Fixation pond, Fecal coliform, Facultative pond, Upward current
Full-Text [PDF 1097 kb]   (2229 Downloads)    
Type of Study: Research | Subject: General
Received: 2008/11/10 | Published: 2002/01/15
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Miranzaeh M B, Mahvi A H. Evaluation of elimination of fecal Coliforms in sewage fixation ponds . Feyz Med Sci J 2002; 5 (4) :54-60
URL: http://feyz.kaums.ac.ir/article-1-350-en.html


Creative Commons License
This open access journal is licensed under a Creative Commons Attribution-NonCommercial ۴.۰ International License. CC BY-NC ۴. Design and publishing by Kashan University of Medical Sciences.
Copyright ۲۰۲۳© Feyz Medical Sciences Journal. All rights reserved.
Volume 5, Issue 4 (Quarterly 2002) Back to browse issues page
مجله علوم پزشکی فیض Feyz Medical Sciences Journal
Persian site map - English site map - Created in 0.05 seconds with 46 queries by YEKTAWEB 4660