<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Feyz Medical Sciences Journal</title>
<title_fa>مجله علوم پزشکی فيض</title_fa>
<short_title>Feyz Med Sci J</short_title>
<subject>Medical Sciences</subject>
<web_url>http://feyz.kaums.ac.ir</web_url>
<journal_hbi_system_id>29</journal_hbi_system_id>
<journal_hbi_system_user>journal29</journal_hbi_system_user>
<journal_id_issn>3060-5806</journal_id_issn>
<journal_id_issn_online>3060-5814</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2024</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>28</volume>
<number>6</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تخمین دُز ورودی پوست و دُز مؤثر نوزادان در آزمون‌های رایج رادیوگرافی در بیمارستان‌های دولتی شهر ساری</title_fa>
	<title>Estimation of skin entrance dose and effective dose in neonates during common radiographic tests in public hospitals in Sari, Iran</title>
	<subject_fa>medicine, paraclinic</subject_fa>
	<subject>medicine, paraclinic</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:11px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;font-family:IRANyekan;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;زمینه و هدف:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; رادیوگرافی نقش مهمی در تشخیص ناهنجاری&#8204;های نوزادان ایفا می&#8204;کند. با توجه به حساسیت بالای نوزادان به پرتوهای یونیزان، اندازه کوچک اندام&#8204;ها، نزدیکی ارگان&#8204;ها به یکدیگر، و طول عمر بیشتر آن&#8204;ها که احتمال بروز آثار زیستی پرتو را افزایش می&#8204;دهد، برآورد دُز دریافتی نوزادان ضروری است. این مطالعه با هدف ارزیابی دُز ورودی پوست&lt;/span&gt; (ESD) &lt;span lang=&quot;FA&quot;&gt;و دُز مؤثر نوزادان بستری در بخش مراقبت&#8204;های ویژه ناشی از آزمون&#8204;های رایج رادیوگرافی انجام شد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;روش&#8204;ها:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; در این مطالعه، دُز ورودی پوست&lt;/span&gt; (ESD) &lt;span lang=&quot;FA&quot;&gt;در ۵۰&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;نوزاد بستری در بخش مراقبت&#8204;های ویژه در آزمون&#8204;های رادیوگرافی از ریه، شکم، لگن و جمجمه محاسبه شد. مقدار کرمای هوا در فاصله یک&#8204;متری از لامپ اشعه ایکس اندازه&#8204;گیری شد. سپس، با درنظرگرفتن فاصله لامپ تا فیلم و ضخامت ناحیه آناتومیک مورد رادیوگرافی، مقدار کرمای هوا در محل ورودی پوست محاسبه گردید.&lt;/span&gt; ESD &lt;span lang=&quot;FA&quot;&gt;با ضرب کرمای هوا در فاکتور پرتوهای برگشتی به دست آمد. همچنین، با استفاده از فاکتورهای تبدیل مناسب، مقدار دُز مؤثر از&lt;/span&gt;ESD &amp;nbsp;محاسبه شد.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;یافته&#8204;ها:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; میانگین &lt;/span&gt;ESD &lt;span lang=&quot;FA&quot;&gt;در آزمون&#8204;های رادیوگرافی از ریه، شکم، لگن و جمجمه به&#8204;ترتیب ۰.۳، ۰.۵۷، ۰.۴۳&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;و ۱.۰۱ میلی&#8204;گری&lt;/span&gt; (mGy) &lt;span lang=&quot;FA&quot;&gt;محاسبه شد.&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;بیشترین دُز مؤثر در رادیوگرافی از شکم و لگن مشاهده گردید.&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;کیلوولتاژ و میلی&#8204;آمپر-ثانیه، به&#8204;عنوان مهم&#8204;ترین عوامل تأثیرگذار بر&lt;/span&gt; ESD&lt;span lang=&quot;FA&quot;&gt;، در رادیوگرافی از ریه به&#8204;ترتیب ۴۷.۲&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;و ۴.۸ گزارش شد. مقدار &lt;/span&gt;ESD &lt;span lang=&quot;FA&quot;&gt;در آزمون&#8204;های رادیوگرافی از ریه و شکم بالاتر از استانداردهای جهانی بود، درحالی&#8204;که مقادیر&lt;/span&gt; ESD &lt;span lang=&quot;FA&quot;&gt;در رادیوگرافی از جمجمه و لگن تفاوت معناداری با مقادیر&lt;/span&gt; DRL &lt;span lang=&quot;FA&quot;&gt;نداشت.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot;&gt;نتیجه&#8204;گیری:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt; نتایج نشان داد که دُز دریافتی نوزادان در رادیوگرافی از ریه و شکم بالاتر از حد استاندارد است. شرایط تکنیکی به&#8204;کاررفته در انجام این آزمون&#8204;ها، به&#8204;ویژه در رادیوگرافی از ریه، با استانداردهای توصیه&#8204;شده مطابقت ندارد. بنابراین، بازبینی و اصلاح تکنیک&#8204;های تصویربرداری در این آزمون&#8204;ها ضروری است. مراکز تصویربرداری پزشکی باید در انتخاب شرایط تابش به&#8204;گونه&#8204;ای عمل کنند که ضمن حفظ کیفیت تصویر، دُز مؤثر دریافتی نوزادان کاهش یابد.&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;برای این منظور، استفاده از ولتاژ بالا&lt;/span&gt; (kV) &lt;span lang=&quot;FA&quot;&gt;و جریان پایین (میلی&#8204;آمپر) در رادیوگرافی از تنه نوزادان (ریه، شکم و لگن) توصیه می&#8204;شود.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;Background and Aim: &lt;/b&gt;Radiography plays a crucial role in diagnosing neonatal abnormalities. Due to the heightened sensitivity of neonates to ionizing radiation, the small size of their body parts, the proximity of their organs, and their longer life expectancy, there is an increased risk of biological effects from radiation exposure. Therefore, estimating the received radiation dose in neonates is essential. This study aimed to evaluate the skin entrance dose (ESD) and effective dose in neonates admitted to the neonatal intensive care unit (NICU) from common radiographic tests.&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;Methods:&lt;/b&gt; In this study, the skin entrance dose (ESD) was measured in 50 neonates in the NICU who underwent chest, abdominal, pelvic, and skull radiography. Air kerma at a distance of one meter from the X-ray tube was measured. The air kerma at the skin entrance site was then calculated, considering the distance from the tube to the film and the thickness of the anatomical region being radiographed. ESD was obtained by multiplying the air kerma by the backscatter factor. Furthermore, the effective dose was computed from the ESD using appropriate conversion factors.&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;Results:&lt;/b&gt; The average ESD for chest, abdominal, pelvic, and skull radiographs were 0.3, 0.57, 0.43, and 1.01 milligray (mGy), respectively. The highest effective dose was observed in abdominal and pelvic radiography. Kilovoltage and milliampere-seconds, as the most significant factors affecting ESD, were reported to be 47.2 and 4.8 for chest radiography. The ESD values for chest and abdominal radiographs were higher than international standards, while the ESD values for skull and pelvic radiographs showed no significant difference from the diagnostic reference levels (DRL).&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;Conclusion:&lt;/b&gt; The results indicate that neonates received higher doses in chest and abdominal radiographs compared to the standard thresholds. The technical conditions used in these radiographic tests, especially for chest radiography, did not align with the recommended standards. Therefore, reviewing and adjusting imaging techniques for these tests is necessary. Medical imaging centers should select exposure conditions that reduce the effective dose received by neonates while maintaining image quality. It is recommended to use high kilovoltage (kV) and low milliampere (mA) settings for radiography of the neonate&amp;#39;s torso (chest, abdomen, and pelvis).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>نوزادان, رادیوگرافی, دُز ورودی پوست, دُز مؤثر, آثار زیستی پرتو</keyword_fa>
	<keyword>Neonates, Radiography, Skin entrance dose, Effective dose, Biological effects of radiation</keyword>
	<start_page>646</start_page>
	<end_page>652</end_page>
	<web_url>http://feyz.kaums.ac.ir/browse.php?a_code=A-10-4664-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Gholamreza</first_name>
	<middle_name></middle_name>
	<last_name>Fallahmohammadi</last_name>
	<suffix></suffix>
	<first_name_fa>غلامرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فلاح محمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>rezfallah@gmail.com</email>
	<code>2900319475328460048344</code>
	<orcid>2900319475328460048344</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Radiology, Faculty of Allied Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی مازندران، ساری، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir</first_name>
	<middle_name></middle_name>
	<last_name>Saemian</last_name>
	<suffix></suffix>
	<first_name_fa>امیر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>صاِئمیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>amirsaemiyan@gmail.com</email>
	<code>2900319475328460048345</code>
	<orcid>0009-0002-3995-2597</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, Faculty of Allied Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی مازندران، ساری، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mobina</first_name>
	<middle_name></middle_name>
	<last_name>Darbayar</last_name>
	<suffix></suffix>
	<first_name_fa>مبینا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دربایار</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>daryabarm0@gmail.com</email>
	<code>2900319475328460048346</code>
	<orcid>0009-0006-0428-7426</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiology, Faculty of Allied Medicine, Mazandaran University of Medical Sciences, Sari, Iran</affiliation>
	<affiliation_fa>گروه رادیولوژی، دانشکده پیراپزشکی، دانشگاه علوم پزشکی مازندران، ساری، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
