[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Indexing Sources::
Guide for Authors::
Online Submission::
Ethics::
Articles archive::
For Reviewers::
Contact us::
::
Basic and Clinical Biochemistry and Nutrition
..
DOAJ
..
CINAHL
..
EBSCO
..
IMEMR
..
ISC
..
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
enamad
..
:: Volume 9, Issue 4 (Quarterly 2006) ::
Feyz 2006, 9(4): 43-49 Back to browse issues page
Accuracy and precision of body temperature measurement with infrared tympanic and axiliary thermometers compared with standard oral mercury thermometer
Ahmad Khosravi , Mohammad Bagher Sohrabi , Hossein Haratipoor , Poune Zolfaghari
Abstract:   (9388 Views)

Background: Monitoring patients’ temperatures is an important aspect of clinical nursing. Oral temperature readings have long been considered as a gold standard. However, oral temperature measurements may be contraindicated in some patients, that is cases with level of consciousness and seizure. Axiliary and tympanic temperature monitoring are often the next choices. We decided to evaluate these methods compared with standard oral temperature readings.

Materials and Methods: Subjects were a convenient sample of 81 adult patients over 17 years old in Shahrood Imam Hussein hospital. The study time course spanned a 1-mounth in December, 2004. Body temperature is measured in the evening using mercury oral and axiliary thermometers and “Omeron” tympanic thermometer.

Results: From 81 patients studied, there were 35(43.2%) males and 46(56.8%) females and their mean age was 46.0 ±19.2 (range 17-85). The mean for oral temperature was 36.9±0.56°C, axiliary: 36.5±0.53 °C, tympanic: 36.5±0.49° C. Oral thermometry identified a fever in 8 of 81 (9.9%) patients. The ROC analysis for determining a cut point with 100% sensitivity is used. For axiliary measurement at 36.95 °C, 82% specificity and for tympanic measurement at 36.45 °C, 55% specificity is recorded. Alpha coronbach for reliability of tympanic thermometer is equal to 0.98. The correlation between right to right and left to right ear temperature were 0.96 and 0.94, respectively. Conclusion: We conclude that axiliary thermometer with carefully use and suitable cut point is an effective instrument. With regard to specificity of tympanic thermometer for detection of fever, we do not recommend electronic tympanic measurement.

Keywords: Accuracy, Precision, Oral thermometer, Axiliary thermometer, Tympanic thermometer
Full-Text [PDF 324 kb]   (66319 Downloads)    
Type of Study: Research | Subject: General
Received: 2008/10/29 | Revised: 2008/10/29 | Published: 2006/01/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khosravi A, Sohrabi M B, Haratipoor H, Zolfaghari P. Accuracy and precision of body temperature measurement with infrared tympanic and axiliary thermometers compared with standard oral mercury thermometer. Feyz 2006; 9 (4) :43-49
URL: http://feyz.kaums.ac.ir/article-1-116-en.html


Creative Commons License
This open access journal is licensed under a Creative Commons Attribution-NonCommercial ۴.۰ International License. CC BY-NC ۴. Design and publishing by Kashan University of Medical Sciences.
Copyright ۲۰۲۳© Feyz Medical Sciences Journal. All rights reserved.
Volume 9, Issue 4 (Quarterly 2006) Back to browse issues page
مجله علوم پزشکی فیض Feyz Medical Sciences Journal
Persian site map - English site map - Created in 0.05 seconds with 46 queries by YEKTAWEB 4645